Sika - Sikaplan G-15 waterproofing membrane
Price on request
discount price
net unit price
37,97zł for m²
minimum trading quantity
the amount of product
40.00 m²
total price
net list price
1 665,20zł
for 40.00 m²
total price
discounted net price
1 518,80zł
for 40.00 m²
price-list
gross unit price 51,20zł
for m²
discount price
gross unit price
46,70zł
for m²
minimum trading quantity
the amount of product
40.00 m²
total price
gross list price
2 048,20zł
for 40.00 m²
total price
gross discount price
1 868,12zł
for 40.00 m²
Product description
Multilayer, reinforced with polyester mesh, synthetic roofing membrane, polymeric, waterproofing based on high-quality polyvinyl chloride (PVC). Contains UV radiation stabilizers and a flame retardant (in accordance with PN-EN 13956). The roof insulation membrane is used to cover flat surfaces of the roof - roof coverings mechanically attached to the roof structure base. Suitable for direct exposure in all climatic zones.
Features
- resistance to the constant exposure to wind
- resistance to common environmental pollutants
- resistance to permanent UV radiation
- hot air welding without open fire
- high vapor permeability
- possibility of recycling
Technical data
- structured surface
- dark gray bottom layer
- effective thickness 1.5 mm (-5% / + 10%) (according to PN-EN 1849-2)
- straightness ≤ 30 mm (according to PN-EN 1848-2)
- flatness ≤ 10 mm (according to PN-EN 1848-2)
- mass per unit area 1.8 kg / m (-5% / + 10% (acc. to PN-EN 1849-2)
- impact resistance: hard substrate ≥ 400 mm; soft substrate ≥ 700 mm (according to PN-EN 12691)
- hail resistance: rigid substrate ≥ 18 m / s; flexible substrate ≥ 30 m / s (according to PN-EN 13583)
- tensile strength: longitudinally (md) ≥ 1000 N / 50 mm; transverse (cmd) ≥ 900 N / 50 mm (according to PN-EN 12311-2)
- elongation: longitudinal (md) ≥ 15%; transverse (cmd) ≥ 15% (according to PN-EN 12311-2)
- dimensional stability: longitudinally (md) ≤ | 0.5 |%; transverse (cmd) ≤ | 0.5 |% - according to PN-EN 1107-2
- tear strength: longitudinally (md) ≥ 150 N; transverse (cmd) ≥ 150 N - according to PN-EN 12310-2
- shear resistance of the joint ≥ 600 N / 50 mm (according to PN-EN 12317-2)
- bendability at low temperatures ≤ -25 C (according to PN-EN 495-5)
- behavior due to external fire B ROOF (t1) <20; B ROOF (t3) <10 - according to PN-EN 13501-5
- reaction to fire class E (according to PN-EN ISO 11925-2, classification according to PN-EN 13501-1)
- resistance to UV radiation (> 5000 h / degree 0; according to PN-EN 1297)
- water vapor permeability = 20,000 (according to PN-EN 1931)
- watertightness according to PN-EN 1928
- application conditions: ambient temperature minimum -15 C / maximum +60 C; substrate temperature minimum -25 C / maximum +60 C
- storage conditions: rolls must be stored at a temperature between +5 C and +30 C, horizontally on pallets, protected against direct sunlight, rain, snow, ice, etc. do not place pallets or other materials on rolls during transport and storage
- length 20 m
Technical data